West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Farakka River Basin: GANGA CPCB Station Code: 5162
Sample Date: 30/03/2022 Sample Time: 14:00  
Human Activities: Fishing Weather: Sunny Water Body: Ganga
Frequency Of Monitoring: Fortnightly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Light Green Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.12   mg/l
  BOD   2.80   mg/l
  Conductivity   460.40   µs/cm
  Dissolved O2(DO)   7.00   mg/l
  E-coli   130   MPN/100ml
  Fecal Coliform   330   MPN/100ml
  Nitrate-N   0.37   mg/l
  pH   8.20   Unit
  Temperature(Water)   32   ⁰C
  Total Coliform   940   MPN/100ml
  Boron   BDL   mg/l
  Calcium   35.48   mg/l
  Chloride   22.99   mg/l
  COD   10.00   mg/l
  Fluoride   0.40   mg/l
  Magnesium   15.14   mg/l
  Nitrite N   0.03   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Potassium   3.80   mg/l
  Sodium   22.40   mg/l
  Sulphate   28.79   mg/l
  Total Alkalinity   160.57   mg/l
  Total Dissolved Solids(TDS)   256.00   mg/l
  Total Fixed Solids(TFS)   230.00   mg/l
  Total Hardness as CaCo3   150.82   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   44.00   mg/l
  Turbidity   29.11   NTU
  Fecal Streptococci   22   MPN/100ml
  Phosphate-P   0.05   mg/l