West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Farakka River Basin: GANGA CPCB Station Code: 5162
Sample Date: 09/02/2022 Sample Time: 17:35  
Human Activities: Barrage area Weather: Foggy Water Body: Ganga
Frequency Of Monitoring: Fortnightly Use Based Class: B Approximate Depth(Bottom/Table): 1.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  BOD   1.70   mg/l
  Conductivity   442.00   µs/cm
  Dissolved O2(DO)   8.00   mg/l
  E-coli   92   MPN/100ml
  Fecal Coliform   330   MPN/100ml
  Fecal Streptococci   11   MPN/100ml
  Nitrate-N   0.49   mg/l
  pH   7.93   Unit
  Temperature(Water)   19   ⁰C
  Total Coliform   700   MPN/100ml
  Boron   BDL   mg/l
  Calcium   57.89   mg/l
  Chloride   15.99   mg/l
  COD   10.00   mg/l
  Fluoride   0.38   mg/l
  Magnesium   7.20   mg/l
  Nitrite N   0.02   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.06   mg/l
  Potassium   3.30   mg/l
  Sodium   14.50   mg/l
  Sulphate   24.69   mg/l
  Total Alkalinity   148.76   mg/l
  Total Dissolved Solids(TDS)   276.00   mg/l
  Total Fixed Solids(TFS)   234.00   mg/l
  Total Hardness as CaCo3   174.07   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   26.00   mg/l
  Turbidity   30.12   NTU
  Ammonia-N   0.21   mg/l