West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: MATHA BHANGA, GOBINDAPUR River Basin: Mathabhanga_Churni CPCB Station Code: 2517
Sample Date: 05/07/2022 Sample Time: 11:50  
Human Activities: Bathing & washing Weather: Sunny Water Body: Mathabhanga at Gobindapur
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.10   mg/l
  BOD   3.29   mg/l
  Conductivity   674.40   µs/cm
  Dissolved O2(DO)   1.50   mg/l
  Fecal Coliform   130000   MPN/100ml
  Fecal Streptococci   1700   MPN/100ml
  Nitrate-N   0.10   mg/l
  pH   7.84   Unit
  Temperature(Water)   33   ⁰C
  Total Coliform   240000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   70.32   mg/l
  Chloride   9.99   mg/l
  COD   13.00   mg/l
  Fluoride   0.17   mg/l
  Magnesium   22.17   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.10   mg/l
  Potassium   5.70   mg/l
  Sodium   14.10   mg/l
  Sulphate   10.86   mg/l
  Total Alkalinity   320.00   mg/l
  Total Dissolved Solids(TDS)   370.00   mg/l
  Total Fixed Solids(TFS)   314.00   mg/l
  Total Hardness as CaCo3   266.67   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   12.00   mg/l
  Turbidity   11.75   NTU