West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: JALANGI, D/S OF KRISHNA NAGAR River Basin: Bhairab_Gobra_Jalangi CPCB Station Code: 2514
Sample Date: 14/01/2020 Sample Time: 08:20  
Human Activities: Bathing & washing Weather: Sunny Clear Water Body: Jalangi at Krishna Nagar
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  BOD   2.65   mg/l
  Conductivity   465.80   µs/cm
  Dissolved O2(DO)   10.50   mg/l
  Nitrate-N   0.41   mg/l
  pH   8.24   Unit
  Temperature   19   ⁰C
  Total Coliform   1300   MPN/100ml
  Boron   BDL   mg/l
  Chloride   11.57   mg/l
  COD   11.83   mg/l
  Fluoride   0.24   mg/l
  Magnesium   18.23   mg/l
  Phenolpthalein Alkanity   9.84   mg/l
  Phosphate-P   0.013   mg/l
  Potassium   3.80   mg/l
  Sulphate   7.11   mg/l
  Total Alkalinity   246.06   mg/l
  Total Dissolved Solids(TDS)   232.00   mg/l
  Total Fixed Solids(TFS)   44.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   14.00   mg/l
  Turbidity   5.86   NTU
  Ammonia-N   0.12   mg/l
  Calcium   60.00   mg/l
  Fecal Coliform   200   MPN/100ml
  Sodium   15.80   mg/l
  Total Hardness as CaCo3   225.00   mg/l