West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: JALANGI, D/S OF KRISHNA NAGAR River Basin: Bhairab_Gobra_Jalangi CPCB Station Code: 2514
Sample Date: 24/03/2022 Sample Time: 13:00  
Human Activities: Bathing & washing Weather: Sunny,Clear Water Body: Jalangi at Krishna Nagar
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.10   mg/l
  BOD   3.00   mg/l
  Conductivity   649.90   µs/cm
  Dissolved O2(DO)   7.50   mg/l
  Fecal Coliform   11000   MPN/100ml
  Fecal Streptococci   490   MPN/100ml
  Nitrate-N   0.12   mg/l
  pH   8.15   Unit
  Temperature(Water)   29   ⁰C
  Total Coliform   24000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   70.81   mg/l
  Chloride   14.99   mg/l
  COD   13.00   mg/l
  Fluoride   0.28   mg/l
  Magnesium   21.87   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.05   mg/l
  Potassium   3.90   mg/l
  Sodium   20.90   mg/l
  Sulphate   7.88   mg/l
  Total Alkalinity   286.89   mg/l
  Total Dissolved Solids(TDS)   328.00   mg/l
  Total Fixed Solids(TFS)   320.00   mg/l
  Total Hardness as CaCo3   266.67   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   10.00   mg/l
  Turbidity   4.31   NTU