West Bengal Pollution Control Board |
Kankinara Laboratory |
Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189 |
Station: JALANGI, D/S OF KRISHNA NAGAR | River Basin: Bhairab_Gobra_Jalangi | CPCB Station Code: 2514 |
Sample Date: 17/11/2021 | Sample Time: 14:00 | |
Human Activities: Bathing & washing | Weather: Sunny,Clear | Water Body: Jalangi at Krishna Nagar |
Frequency Of Monitoring: Quarterly | Use Based Class: C | Approximate Depth(Bottom/Table): 2.00 m |
Color & Intensity: Clear | Odour: Odour free | Visible effluent discharge: None |
Water Quality | ||
---|---|---|
Parameter | Test Result | Unit |
Ammonia-N | 0.21 | mg/l |
BOD | 2.30 | mg/l |
Conductivity | 520.20 | µs/cm |
Dissolved O2(DO) | 5.80 | mg/l |
Fecal Coliform | 33000 | MPN/100ml |
Fecal Streptococci | 330 | MPN/100ml |
Nitrate-N | 0.16 | mg/l |
pH | 7.58 | Unit |
Temperature(Water) | 26 | ⁰C |
Total Coliform | 49000 | MPN/100ml |
Boron | BDL | mg/l |
Calcium | 58.00 | mg/l |
Chloride | 11.99 | mg/l |
COD | 13.00 | mg/l |
Fluoride | 0.42 | mg/l |
Magnesium | 36.00 | mg/l |
Phenolpthalein Alkanity | Nil | mg/l |
Phosphate-P | 0.19 | mg/l |
Potassium | 3.40 | mg/l |
Sodium | 15.00 | mg/l |
Sulphate | 13.66 | mg/l |
Total Alkalinity | 255.47 | mg/l |
Total Dissolved Solids(TDS) | 358.00 | mg/l |
Total Fixed Solids(TFS) | 274.00 | mg/l |
Total Hardness as CaCo3 | 292.00 | mg/l |
Total Kjeldahl Nitrogen(TKN) | mg/l | |
Total Suspended Solids(TSS) | 10.00 | mg/l |
Turbidity | 9.68 | NTU |