West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 09/03/2021 Sample Time: 14:30  
Human Activities: Bathing & washing Weather: Sunny Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.19   mg/l
  BOD   2.05   mg/l
  Conductivity   401.20   µs/cm
  Dissolved O2(DO)   7.20   mg/l
  E-coli   2000   MPN/100ml
  Fecal Coliform   4500   MPN/100ml
  Fecal Streptococci   110   MPN/100ml
  Nitrate-N   0.51   mg/l
  pH   8.25   Unit
  Temperature(Water)   27   ⁰C
  Total Coliform   7800   MPN/100ml
  Boron   BDL   mg/l
  Calcium   46.49   mg/l
  Chloride   13.00   mg/l
  COD   8.00   mg/l
  Fluoride   0.26   mg/l
  Magnesium   10.69   mg/l
  Nitrite N   0.02   mg/l
  Phenolpthalein Alkanity   4.07   mg/l
  Phosphate-P   0.07   mg/l
  Potassium   4.40   mg/l
  Sodium   19.70   mg/l
  Sulphate   18.75   mg/l
  Total Alkalinity   140.24   mg/l
  Total Dissolved Solids(TDS)   182.00   mg/l
  Total Fixed Solids(TFS)   180.00   mg/l
  Total Hardness as CaCo3   160.00   mg/l
  Total Suspended Solids(TSS)   26.00   mg/l
  Turbidity   22.70   NTU
  Total Kjeldahl Nitrogen(TKN)      mg/l