West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 04/03/2020 Sample Time: 13:30  
Human Activities: Bathing & washing Weather: Sunny Clear Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.10   mg/l
  BOD   3.00   mg/l
  Conductivity   354.50   µs/cm
  Dissolved O2(DO)   7.20   mg/l
  E-coli   2000   MPN/100ml
  Fecal Coliform   4000   MPN/100ml
  Fecal Streptococci   130   MPN/100ml
  Nitrate-N   0.61   mg/l
  pH   8.45   Unit
  Temperature   24   ⁰C
  Total Coliform   13000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   32.72   mg/l
  Chloride   13.50   mg/l
  COD   10.00   mg/l
  Fluoride   0.23   mg/l
  Magnesium   13.64   mg/l
  Nitrite N   0.02   mg/l
  Phenolpthalein Alkanity   11.28   mg/l
  Phosphate-P   0.0835   mg/l
  Potassium   3.60   mg/l
  Sodium   18.90   mg/l
  Sulphate   18.77   mg/l
  Total Alkalinity   150.38   mg/l
  Total Dissolved Solids(TDS)   210.00   mg/l
  Total Fixed Solids(TFS)   24.00   mg/l
  Total Hardness as CaCo3   137.76   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   58.00   mg/l
  Turbidity   56.80   NTU