West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 01/11/2019 Sample Time: 08:55  
Human Activities: Bathing & washing Weather: Sunny Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  BOD   3.0   mg/l
  Conductivity   268.1   µs/cm
  Dissolved O2(DO)   4.7   mg/l
  E-coli   22000   MPN/100ml
  Fecal Coliform   140000   MPN/100ml
  Fecal Streptococci   230   MPN/100ml
  Nitrate-N   0.54   mg/l
  pH   7.85   Unit
  Temperature   27   ⁰C
  Total Coliform   170000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   26.92   mg/l
  Chloride   8.68   mg/l
  COD   8.4   mg/l
  Fluoride   0.18   mg/l
  Magnesium   8.18   mg/l
  Nitrite N   BDL   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.055   mg/l
  Potassium   3.70   mg/l
  Sodium   12.40   mg/l
  Sulphate   15.09   mg/l
  Total Alkalinity   100.01   mg/l
  Total Dissolved Solids(TDS)   140.0   mg/l
  Total Fixed Solids(TFS)   36.0   mg/l
  Total Hardness as CaCo3   100.96   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Ammonia-N   0.17   mg/l
  Total Suspended Solids(TSS)   58.0   mg/l
  Turbidity   77.2   NTU