West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 20/12/2021 Sample Time: 14:25  
Human Activities: Bathing & washing,Navigation Weather: Sunny,Clear Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  Dissolved O2(DO)   6.30   mg/l
  Conductivity   385.70   µs/cm
  Fluoride   0.49   mg/l
  Total Suspended Solids(TSS)   36.00   mg/l
  E-coli   2300   MPN/100ml
  Fecal Coliform   7900   MPN/100ml
  Fecal Streptococci   230   MPN/100ml
  Nitrate-N   0.63   mg/l
  pH   8.21   Unit
  Temperature(Water)   20   ⁰C
  Total Coliform   13000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   46.25   mg/l
  Chloride   11.99   mg/l
  COD   9.00   mg/l
  Magnesium   24.30   mg/l
  Nitrite N   0.01   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.13   mg/l
  Potassium   3.60   mg/l
  Sodium   12.70   mg/l
  Sulphate   19.84   mg/l
  Total Alkalinity   149.63   mg/l
  Total Dissolved Solids(TDS)   244.00   mg/l
  Total Fixed Solids(TFS)   220.00   mg/l
  Total Hardness as CaCo3   215.38   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Turbidity   29.01   NTU
  Ammonia-N   0.34   mg/l
  BOD   2.00   mg/l