West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 27/08/2021 Sample Time: 15:10  
Human Activities: Bathing & washing,Navagation Weather: Cloudy,Rainy Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.10   mg/l
  BOD   3.19   mg/l
  Conductivity   232.30   µs/cm
  Dissolved O2(DO)   6.60   mg/l
  E-coli   23000   MPN/100ml
  Fecal Coliform   49000   MPN/100ml
  Fecal Streptococci   1100   MPN/100ml
  Nitrate-N   0.52   mg/l
  pH   7.85   Unit
  Temperature(Water)   30   ⁰C
  Total Coliform   94000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   28.29   mg/l
  Chloride   6.84   mg/l
  COD   11.00   mg/l
  Fluoride   0.96   mg/l
  Magnesium   12.39   mg/l
  Nitrite N   0.02   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.19   mg/l
  Potassium   3.40   mg/l
  Sodium   10.50   mg/l
  Sulphate   12.72   mg/l
  Total Alkalinity   98.15   mg/l
  Total Dissolved Solids(TDS)   146.00   mg/l
  Total Fixed Solids(TFS)   138.00   mg/l
  Total Hardness as CaCo3   121.57   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   192.00   mg/l
  Turbidity   157.00   NTU