West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 15/06/2021 Sample Time: 10:20  
Human Activities: Bathing & washing Weather: Cloudy Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  BOD   4.20   mg/l
  Conductivity   267.80   µs/cm
  Dissolved O2(DO)   6.50   mg/l
  E-coli   7800   MPN/100ml
  Fecal Coliform   23000   MPN/100ml
  Fecal Streptococci   230   MPN/100ml
  Nitrate-N   0.57   mg/l
  pH   7.81   Unit
  Temperature(Water)   30   ⁰C
  Total Coliform   33000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   37.52   mg/l
  Chloride   9.00   mg/l
  COD   11.00   mg/l
  Magnesium   19.65   mg/l
  Nitrite N   0.01   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.05   mg/l
  Potassium   3.60   mg/l
  Sodium   9.80   mg/l
  Sulphate   19.72   mg/l
  Total Alkalinity   100.00   mg/l
  Total Dissolved Solids(TDS)   104.00   mg/l
  Total Hardness as CaCo3   174.47   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   96.00   mg/l
  Turbidity   75.40   NTU
  Ammonia-N   0.19   mg/l
  Fluoride   0.49   mg/l
  Total Fixed Solids(TFS)   118.00   mg/l