West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 06/05/2021 Sample Time: 14:00  
Human Activities: Bathing & washing Weather: Sunny Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.13   mg/l
  BOD   2.55   mg/l
  Conductivity   423.20   µs/cm
  Dissolved O2(DO)   6.40   mg/l
  E-coli   4500   MPN/100ml
  Fecal Streptococci   330   MPN/100ml
  Nitrate-N   0.41   mg/l
  pH   8.05   Unit
  Total Coliform   13000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   49.00   mg/l
  Chloride   15.00   mg/l
  COD   9.52   mg/l
  Fluoride   0.52   mg/l
  Magnesium   4.00   mg/l
  Nitrite N   0.03   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.07   mg/l
  Potassium   4.20   mg/l
  Sodium   16.60   mg/l
  Sulphate   20.96   mg/l
  Total Alkalinity   143.44   mg/l
  Total Fixed Solids(TFS)   202.00   mg/l
  Total Hardness as CaCo3   137.25   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   62.00   mg/l
  Turbidity   50.50   NTU
  Fecal Coliform   7800   MPN/100ml
  Temperature(Water)   30   ⁰C
  Total Dissolved Solids(TDS)   226.00   mg/l