West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Nabadip Ghoshpara near Monipurghat River Basin: GANGA CPCB Station Code: 2511
Sample Date: 26/04/2021 Sample Time: 13:40  
Human Activities: Bathing & Washing Weather: Sunny, Clear Water Body: Ground water at Geokhali
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.14   mg/l
  BOD   1.45   mg/l
  Conductivity   404.40   µs/cm
  Dissolved O2(DO)   7.20   mg/l
  E-coli   1300   MPN/100ml
  Fecal Coliform   2200   MPN/100ml
  Fecal Streptococci   220   MPN/100ml
  Nitrate-N   0.36   mg/l
  pH   8.35   Unit
  Temperature(Water)   31   ⁰C
  Total Coliform   4900   MPN/100ml
  Boron   BDL   mg/l
  Calcium   41.75   mg/l
  Chloride   15.00   mg/l
  COD   7.62   mg/l
  Fluoride   0.45   mg/l
  Magnesium   15.19   mg/l
  Nitrite N   0.01   mg/l
  Phenolpthalein Alkanity   6.10   mg/l
  Phosphate-P   0.11   mg/l
  Potassium   4.00   mg/l
  Sodium   16.80   mg/l
  Sulphate   25.95   mg/l
  Total Alkalinity   146.34   mg/l
  Total Dissolved Solids(TDS)   268.00   mg/l
  Total Fixed Solids(TFS)   176.00   mg/l
  Total Hardness as CaCo3   166.67   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   28.00   mg/l
  Turbidity   26.80   NTU