West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: KALYANI INDUSTRIAL AREA, NADIA, WEST BENGAL River Basin: GANGA CPCB Station Code: 1771
Sample Date: 21/04/2022 Sample Time: 11:55  
Human Activities: Pipe line water supply Weather: Sunny,Clear Water Body: Ground water at Kalyani
Frequency Of Monitoring: Halfyearly Use Based Class: A Approximate Depth(Bottom/Table): 122.00 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Nitrate-N   0.07   mg/l
  pH   7.38   Unit
  Fluoride   0.17   mg/l
  Magnesium   44.26   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.01   mg/l
  Potassium   2.80   mg/l
  Sodium   14.60   mg/l
  Turbidity   13.06   NTU
  Arsenic   0.012   mg/l
  Cadmium   BDL   mg/l
  Chromium Total   BDL   mg/l
  Copper   BDL   mg/l
  Iron   1.85   mg/l
  Lead   0.009   mg/l
  Mercury   BDL   mg/l
  Nickel   BDL   mg/l
  Zinc   BDL   mg/l
  a-BHC   NT   ppb
  a-Endosulphan   NT   ppb
  Aldrin   NT   ppb
  Anilophos   NT   ppb
  b-Endosulphan   NT   ppb
  Chlorpyriphos   NT   ppb
  Dieldrin   NT   ppb
  g-BHC   NT   ppb
  Malathion   BDL   ppb
  Methyl Parathion   BDL   ppb
  o,p-DDT   NT   ppb
  p,p-DDT   NT   ppb
  Sulphate   13.51   mg/l
  Total Alkalinity   317.31   mg/l
  Total Dissolved Solids(TDS)   524.00   mg/l
  Ammonia-N   0.52   mg/l
  BOD   0.10   mg/l
  Conductivity   954.40   µs/cm
  Fecal Coliform   <1.1   MPN/100ml
  Temperature(Water)   29   ⁰C
  Total Coliform   1.1   MPN/100ml
  Boron   BDL   mg/l
  Calcium   93.04   mg/l
  Chloride   83.97   mg/l
  COD   2.00   mg/l
  Total Fixed Solids(TFS)   452.00   mg/l
  Total Hardness as CaCo3   414.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   8.00   mg/l