West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Gorabazar River Basin: GANGA CPCB Station Code: 10160
Sample Date: 09/09/2020 Sample Time: 13:40  
Human Activities: Bathing & washing,Burning of Dead Body Weather: Sunny, Clear Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  BOD   2.45   mg/l
  Dissolved O2(DO)   6.00   mg/l
  E-coli   14000   MPN/100ml
  Fecal Streptococci   1300   MPN/100ml
  Nitrate-N   0.31   mg/l
  pH   7.72   Unit
  Total Coliform   80000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   33.33   mg/l
  Chloride   9.19   mg/l
  Fluoride   0.27   mg/l
  Magnesium   5.39   mg/l
  Nitrite N   0.11   mg/l
  Phosphate-P   0.10   mg/l
  Potassium   6.20   mg/l
  Sodium   18.80   mg/l
  Total Alkalinity   117.02   mg/l
  Total Dissolved Solids(TDS)   112.00   mg/l
  Total Fixed Solids(TFS)   208.00   mg/l
  Total Hardness as CaCo3   105.55   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Turbidity   134.00   NTU
  Ammonia-N   0.18   mg/l
  Conductivity   261.60   µs/cm
  Fecal Coliform   27000   MPN/100ml
  Temperature(Water)   32   ⁰C
  COD   12.49   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Sulphate   15.20   mg/l
  Total Suspended Solids(TSS)   138.00   mg/l