West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Gorabazar River Basin: GANGA CPCB Station Code: 10160
Sample Date: 25/06/2020 Sample Time: 11:20  
Human Activities: Bathing & washing,Burning of Dead Body Weather: Cloudy,Humid Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Nitrate-N   0.47   mg/l
  pH   8.01   Unit
  Temperature(Water)   30   ⁰C
  Total Coliform   130000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   29.41   mg/l
  Chloride   12.00   mg/l
  COD   6.15   mg/l
  Fluoride   0.23   mg/l
  Magnesium   5.96   mg/l
  Nitrite N   0.02   mg/l
  BOD   1.30   mg/l
  Conductivity   219.10   µs/cm
  Dissolved O2(DO)   7.50   mg/l
  E-coli   27000   MPN/100ml
  Fecal Streptococci   300   MPN/100ml
  Fecal Coliform   80000   MPN/100ml
  Total Fixed Solids(TFS)   118.00   mg/l
  Total Hardness as CaCo3   98.08   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   48.00   mg/l
  Turbidity   57.30   NTU
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.09   mg/l
  Potassium   4.3   mg/l
  Sodium   11.7   mg/l
  Sulphate   25.43   mg/l
  Total Alkalinity   95.42   mg/l
  Total Dissolved Solids(TDS)   138.00   mg/l
  Ammonia-N   0.11   mg/l