West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Gorabazar River Basin: GANGA CPCB Station Code: 10160
Sample Date: 21/06/2022 Sample Time: 14:40  
Human Activities: Bathing & washing Weather: Cloudy Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.47   mg/l
  BOD   1.60   mg/l
  Conductivity   230.00   µs/cm
  Dissolved O2(DO)   6.10   mg/l
  E-coli   4500   MPN/100ml
  Fecal Coliform   17000   MPN/100ml
  Fecal Streptococci   330   MPN/100ml
  Nitrate-N   0.30   mg/l
  pH   7.94   Unit
  Temperature(Water)   30   ⁰C
  Total Coliform   22000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   21.86   mg/l
  Chloride   5.99   mg/l
  COD   8.00   mg/l
  Fluoride   0.10   mg/l
  Magnesium   8.84   mg/l
  Nitrite N   0.03   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.06   mg/l
  Potassium   4.40   mg/l
  Sodium   10.10   mg/l
  Sulphate   15.92   mg/l
  Total Alkalinity   83.97   mg/l
  Total Dissolved Solids(TDS)   136.00   mg/l
  Total Fixed Solids(TFS)   162.00   mg/l
  Total Hardness as CaCo3   90.91   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   136.00   mg/l
  Turbidity   115.30   NTU