West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Gorabazar River Basin: GANGA CPCB Station Code: 10160
Sample Date: 19/01/2022 Sample Time: 11:30  
Human Activities: Bathing & washing Weather: Sunny,Clear Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.15   mg/l
  BOD   1.55   mg/l
  Conductivity   459.20   µs/cm
  Dissolved O2(DO)   8.80   mg/l
  E-coli   7800   MPN/100ml
  Fecal Coliform   23000   MPN/100ml
  Fecal Streptococci   700   MPN/100ml
  Nitrate-N   0.64   mg/l
  pH   8.18   Unit
  Temperature(Water)   16   ⁰C
  Total Coliform   33000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   54.51   mg/l
  Chloride   11.99   mg/l
  COD   9.00   mg/l
  Fluoride   0.34   mg/l
  Magnesium   20.41   mg/l
  Nitrite N   0.02   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.06   mg/l
  Potassium   3.40   mg/l
  Sodium   15.10   mg/l
  Sulphate   21.95   mg/l
  Total Alkalinity   161.29   mg/l
  Total Dissolved Solids(TDS)   262.00   mg/l
  Total Fixed Solids(TFS)   236.00   mg/l
  Total Hardness as CaCo3   220.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   32.00   mg/l
  Turbidity   23.73   NTU