West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Gorabazar River Basin: GANGA CPCB Station Code: 10160
Sample Date: 15/06/2021 Sample Time: 13:45  
Human Activities: Bathing & washing Weather: Cloudy Water Body: River Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.19   mg/l
  BOD   3.00   mg/l
  Conductivity   255.50   µs/cm
  Dissolved O2(DO)   5.80   mg/l
  E-coli   13000   MPN/100ml
  Fecal Coliform   49000   MPN/100ml
  Fecal Streptococci   1300   MPN/100ml
  Nitrate-N   0.53   mg/l
  pH   7.78   Unit
  Temperature(Water)   29   ⁰C
  Total Coliform   130000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   30.70   mg/l
  Chloride   9.00   mg/l
  COD   11.00   mg/l
  Fluoride   0.40   mg/l
  Magnesium   14.48   mg/l
  Nitrite N   0.05   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.13   mg/l
  Potassium   3.60   mg/l
  Sodium   8.90   mg/l
  Sulphate   17.17   mg/l
  Total Alkalinity   95.83   mg/l
  Total Dissolved Solids(TDS)   112.00   mg/l
  Total Fixed Solids(TFS)   138.00   mg/l
  Total Hardness as CaCo3   136.17   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   72.00   mg/l
  Turbidity   61.80   NTU