West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Baharampore West Bengal River Basin: GANGA CPCB Station Code: 1080
Sample Date: 20/03/2020 Sample Time: 13;30  
Human Activities: Bathing,Washing Weather: Sunny,clear Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  pH   8.54   Unit
  E-coli   200   MPN/100ml
  Fecal Streptococci   60   MPN/100ml
  Dissolved O2(DO)   8.80   mg/l
  Fecal Coliform   800   MPN/100ml
  Temperature   25   ⁰C
  Ammonia-N   0.11   mg/l
  BOD   4.10   mg/l
  Conductivity   410.20   µs/cm
  Boron   BDL   mg/l
  Calcium   29.3   mg/l
  Chloride   14.99   mg/l
  COD   10.40   mg/l
  Fluoride   0.22   mg/l
  Magnesium   16.36   mg/l
  Nitrite N   0.02   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.053   mg/l
  Potassium   3.90   mg/l
  Sodium   18.10   mg/l
  Sulphate   22.35   mg/l
  Total Alkalinity   149.26   mg/l
  Total Dissolved Solids(TDS)   220.00   mg/l
  Total Fixed Solids(TFS)   54.00   mg/l
  Total Hardness as CaCo3   140.58   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   22.00   mg/l
  Turbidity   81.30   NTU
  Nitrate-N   0.38   mg/l
  Total Coliform   1300   MPN/100ml