West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Baharampore West Bengal River Basin: GANGA CPCB Station Code: 1080
Sample Date: 11/01/2019 Sample Time: 13:00  
Human Activities: Bathing, Washing Weather: Clear Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: C Approximate Depth(Bottom/Table): 2.50 m 
Color & Intensity: Turbid Odour: None Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  pH   8.24   Unit
  Magnesium   9.00   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.03   mg/l
  Potassium   3.70   mg/l
  Sodium   19.10   mg/l
  Dissolved O2(DO)   11.20   mg/l
  Fecal Coliform   80000   MPN/100ml
  Nitrate-N   0.39   mg/l
  Ammonia-N   0.20   mg/l
  BOD   3.65   mg/l
  Temperature   19.0   ⁰C
  Total Coliform   110000   MPN/100ml
  Boron   NT   mg/l
  Calcium   38.00   mg/l
  Chloride   17.35   mg/l
  COD   7.70   mg/l
  Fluoride   0.28   mg/l
  Conductivity   365.00   µs/cm
  Total Kjeldahl Nitrogen(TKN)   0.81   mg/l
  Total Suspended Solids(TSS)   36.00   mg/l
  Total Alkalinity   150.00   mg/l
  Total Dissolved Solids(TDS)   192.00   mg/l
  Total Fixed Solids(TFS)   108.00   mg/l
  Turbidity   52.00   NTU
  Sulphate   13.82   mg/l
  Total Hardness as CaCo3   149.00   mg/l