West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: Ganga at Baharampore West Bengal River Basin: GANGA CPCB Station Code: 1080
Sample Date: 24/11/2021 Sample Time: 14:20  
Human Activities: Bathing & washing,Navigation,Fishing Weather: Sunny,Clear Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: C Approximate Depth(Bottom/Table): 1.00 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.16   mg/l
  BOD   1.65   mg/l
  Conductivity   333.20   µs/cm
  Dissolved O2(DO)   7.10   mg/l
  E-coli   49000   MPN/100ml
  Fecal Coliform   110000   MPN/100ml
  Fecal Streptococci   1100   MPN/100ml
  Nitrate-N   0.70   mg/l
  pH   8.02   Unit
  Temperature(Water)   24   ⁰C
  Total Coliform   240000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   41.62   mg/l
  Chloride   7.99   mg/l
  COD   10.00   mg/l
  Fluoride   0.56   mg/l
  Magnesium   18.69   mg/l
  Nitrite N   0.01   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.11   mg/l
  Potassium   3.90   mg/l
  Sodium   11.00   mg/l
  Sulphate   24.12   mg/l
  Total Alkalinity   132.25   mg/l
  Total Dissolved Solids(TDS)   236.00   mg/l
  Total Fixed Solids(TFS)   254.00   mg/l
  Total Hardness as CaCo3   180.77   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   132.00   mg/l
  Turbidity   155.80   NTU