West Bengal Pollution Control Board

Haldia Laboratory

Block-05 at 40 Flats Complex,Adjacent to Priyambada Housing Complex,Basudevpur, P.O. Khanjanchak, Haldia, Purba Medinipore - 721602



Station: D/S OF RUPNARAYAN AT KOLAGHAT, NEAR KOLAGHAT RAIL BRIDGE NO.3 River Basin: Rupnarayan CPCB Station Code: 2509
Sample Date: 07/01/2019 Sample Time: 13:20 hrs.  
Human Activities: Fisging,Navigation,Bathing Weather: Clear Water Body: Rupnarayan at Kolaghat
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 1.20 m 
Color & Intensity: Turbid Odour: None Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  BOD   2.05   mg/l
  Conductivity   414.00   µs/cm
  Fecal Coliform   11000.00   MPN/100ml
  Nitrate-N   0.47   mg/l
  pH   7.35   Unit
  Temperature   20.0   ⁰C
  Total Coliform   28000.00   MPN/100ml
  Boron   BDL   mg/l
  Calcium   30.30   mg/l
  COD   6.36   mg/l
  Fluoride   0.34   mg/l
  Ammonia-N   BDL   mg/l
  Total Alkalinity   128.71   mg/l
  Total Dissolved Solids(TDS)   310.0   mg/l
  Total Fixed Solids(TFS)   160.0   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   288.00   mg/l
  Total Hardness as CaCo3   161.60   mg/l
  Turbidity   198.0   NTU
  Dissolved O2(DO)   8.90   mg/l
  Chloride   120.53   mg/l
  Magnesium   20.86   mg/l
  Phenolpthalein Alkanity   6.33   mg/l
  Phosphate-P   0.09   mg/l
  Potassium   2.47   mg/l
  Sodium   39.25   mg/l
  Sulphate   19.69   mg/l