West Bengal Pollution Control Board

Haldia Laboratory

Block-05 at 40 Flats Complex,Adjacent to Priyambada Housing Complex,Basudevpur, P.O. Khanjanchak, Haldia, Purba Medinipore - 721602



Station: D/S OF RUPNARAYAN AT KOLAGHAT, NEAR KOLAGHAT RAIL BRIDGE NO.3 River Basin: Rupnarayan CPCB Station Code: 2509
Sample Date: 23/06/2022 Sample Time: 15:00  
Human Activities: Fishing and Bathing Weather: Clear Water Body: Rupnarayan at Kolaghat
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 1.50 m 
Color & Intensity: Turbid Odour: None Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   BDL   mg/l
  BOD   1.65   mg/l
  Conductivity   481.20   µs/cm
  Dissolved O2(DO)   6.20   mg/l
  Fecal Coliform   3300   MPN/100ml
  Fecal Streptococci   200   MPN/100ml
  Nitrate-N   0.56   mg/l
  pH   7.59   Unit
  Temperature(Water)   32.0   ⁰C
  Total Coliform   7000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   49.00   mg/l
  Chloride   282.89   mg/l
  COD   13.00   mg/l
  Fluoride   0.42   mg/l
  Magnesium   37.00   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.16   mg/l
  Potassium   4.20   mg/l
  Sodium   41.20   mg/l
  Sulphate   38.18   mg/l
  Total Alkalinity   56.00   mg/l
  Total Dissolved Solids(TDS)   404.00   mg/l
  Total Fixed Solids(TFS)   610.00   mg/l
  Total Hardness as CaCo3   140.00   mg/l
  Total Suspended Solids(TSS)   236.00   mg/l
  Turbidity   254.00   NTU