West Bengal Pollution Control Board

Haldia Laboratory

Block-05 at 40 Flats Complex,Adjacent to Priyambada Housing Complex,Basudevpur, P.O. Khanjanchak, Haldia, Purba Medinipore - 721602



Station: Tube well inside Mecheda Bus Stand River Basin: GANGA CPCB Station Code: 4735
Sample Date: 18/04/2022 Sample Time: 15:30  
Human Activities: Drinking Weather: Clear Water Body: Well
Frequency Of Monitoring: Halfyearly Use Based Class: A Approximate Depth(Bottom/Table): 300.00 m 
Color & Intensity: Clear Odour: None Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   BDL   mg/l
  BOD   0.95   mg/l
  Conductivity   980.70   µs/cm
  Fecal Coliform   NIL   MPN/100ml
  Nitrate-N   0.18   mg/l
  pH   7.46   Unit
  Temperature(Water)   29.0   ⁰C
  Total Coliform   NIL   MPN/100ml
  Boron   BDL   mg/l
  Calcium   104.00   mg/l
  Chloride   51.86   mg/l
  COD   4.90   mg/l
  Fluoride   0.23   mg/l
  Magnesium   21.00   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.11   mg/l
  Potassium   4.41   mg/l
  Sodium   131.43   mg/l
  Sulphate   24.92   mg/l
  Total Alkalinity   400.00   mg/l
  Total Dissolved Solids(TDS)   620.00   mg/l
  Total Fixed Solids(TFS)   566.00   mg/l
  Total Hardness as CaCo3   346.00   mg/l
  Total Suspended Solids(TSS)   14.00   mg/l
  Turbidity   2.78   NTU
  Arsenic   BDL   mg/l
  Cadmium   BDL   mg/l
  Chromium Total   BDL   mg/l
  Copper   BDL   mg/l
  Iron   0.46   mg/l
  Lead   BDL   mg/l
  Mercury   BDL   mg/l
  Nickel   BDL   mg/l
  Zinc   BDL   mg/l
  a-BHC   BDL   ppb
  a-Endosulphan   BDL   ppb
  Aldrin   BDL   ppb
  Anilophos   BDL   ppb
  b-Endosulphan   BDL   ppb
  Chlorpyriphos   BDL   ppb
  Dieldrin   BDL   ppb
  g-BHC   BDL   ppb
  Malathion   BDL   ppb
  Methyl Parathion   BDL   ppb
  o,p-DDT   BDL   ppb
  p,p-DDT   BDL   ppb