West Bengal Pollution Control Board

Central Laboratory

Paribesh Bhawan, 10A, Block LA, Sector III, Salt Lake City, Kolkata 700 106. (033) 2335-5953



Station: Adi ganga at Jirat Bridge (High Tide) River Basin: GANGA CPCB Station Code: null
Sample Date: 13/08/2019 Sample Time: 11:15  
Human Activities: Bathing & washing Weather: Cloudy Water Body: ADI GANGA
Frequency Of Monitoring: Quarterly Use Based Class: E Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  BOD   1.90   mg/l
  Dissolved O2(DO)   4.50   mg/l
  Fecal Coliform   70000   MPN/100ml
  pH   7.51   Unit
  Temperature   30.0   ⁰C
  Total Coliform   140000   MPN/100ml
  COD   4.42   mg/l
  Total Suspended Solids(TSS)   98.00   mg/l