West Bengal Pollution Control Board

Central Laboratory

Paribesh Bhawan, 10A, Block LA, Sector III, Salt Lake City, Kolkata 700 106. (033) 2335-5953



Station: Ganga at Dakshmineswar, West Bengal River Basin: GANGA CPCB Station Code: 1053
Sample Date: 20/04/2021 Sample Time: 12:10  
Human Activities: Bathing & washing, Navigation Weather: Sunny Water Body: Ganga
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Light brown Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  BOD   3.20   mg/l
  Conductivity   402.90   µs/cm
  Dissolved O2(DO)   6.20   mg/l
  E-coli   23000   MPN/100ml
  Fecal Coliform   31000   MPN/100ml
  Fecal Streptococci   170   MPN/100ml
  Nitrate-N   0.18   mg/l
  pH   7.73   Unit
  Temperature(Water)   32.0   ⁰C
  Total Coliform   79000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   46.40   mg/l
  Chloride   19.50   mg/l
  COD   15.00   mg/l
  Fluoride   0.36   mg/l
  Magnesium   8.26   mg/l
  Nitrite N   0.03   mg/l
  Phenolpthalein Alkanity   5.20   mg/l
  Phosphate-P   0.06   mg/l
  Potassium   11.97   mg/l
  Sodium   13.75   mg/l
  Sulphate   24.06   mg/l
  Total Alkalinity   160.00   mg/l
  Total Dissolved Solids(TDS)   188.00   mg/l
  Total Fixed Solids(TFS)   106.00   mg/l
  Total Hardness as CaCo3   150.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   32.00   mg/l
  Turbidity   41.00   NTU
  Ammonia-N   0.28   mg/l