West Bengal Pollution Control Board

Central Laboratory

Paribesh Bhawan, 10A, Block LA, Sector III, Salt Lake City, Kolkata 700 106. (033) 2335-5953



Station: Ganga at Uluberia, West Bengal River Basin: GANGA CPCB Station Code: 1052
Sample Date: 13/04/2020 Sample Time: 12:05  
Human Activities: none Weather: Sunny Water Body: Ganga
Frequency Of Monitoring: Continious Use Based Class: A Approximate Depth(Bottom/Table): 1.50 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Dissolved O2(DO)   4.00   mg/l
  Fecal Coliform   17000   MPN/100ml
  Nitrate-N   2.02   mg/l
  pH   7.01   Unit
  Temperature(Water)   33.0   ⁰C
  Total Coliform   30000   MPN/100ml
  Calcium   41.60   mg/l
  Chloride   28.99   mg/l
  COD   21.74   mg/l
  Magnesium   12.64   mg/l
  Phosphate-P   0.16   mg/l
  Potassium   2.63   mg/l
  Sodium   20.98   mg/l
  Sulphate   33.43   mg/l
  Total Alkalinity   144.00   mg/l
  Total Dissolved Solids(TDS)   196.00   mg/l
  Total Hardness as CaCo3   156.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Turbidity   187.00   NTU
  Arsenic   BDL   mg/l
  Cadmium   BDL   mg/l
  Chromium Total   BDL   mg/l
  Copper   BDL   mg/l
  Iron   0.59   mg/l
  Lead   BDL   mg/l
  Mercury   BDL   mg/l
  Nickel   BDL   mg/l
  Zinc   BDL   mg/l
  a-BHC   NT   ppb
  a-Endosulphan   NT   ppb
  Aldrin   NT   ppb
  Anilophos   NT   ppb
  b-Endosulphan   BDL   ppb
  Chlorpyriphos   BDL   ppb
  Dieldrin   NT   ppb
  g-BHC   BDL   ppb
  Malathion   BDL   ppb
  Methyl Parathion   NT   ppb
  o,p-DDT   NT   ppb
  p,p-DDT   BDL   ppb
  BOD   1.05   mg/l
  Conductivity   323.00   µs/cm
  Ammonia-N   0.11   mg/l