West Bengal Pollution Control Board

Hooghly Laboratory

Himalaya Bhawan, Delhi Road, Dankuni, Hooghly



Station: GANGA AT SERAMPORE, WEST BENGAL River Basin: GANGA CPCB Station Code: 1472
Sample Date: 02/09/2020 Sample Time: 09:45  
Human Activities: Bathing and washing Weather: Sunny,clear Water Body: GANGA AT SERAMPORE
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour Free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Chloride   13.27   mg/l
  COD   14.40   mg/l
  Conductivity   303.60   µs/cm
  Dissolved O2(DO)   4.80   mg/l
  pH   7.70   Unit
  Temperature(Water)   31   ⁰C
  Nitrate-N   0.42   mg/l
  Calcium   37.78   mg/l
  E-coli   7900   MPN/100ml
  Boron   BDL   mg/l
  Fecal Coliform   17000   MPN/100ml
  Fecal Streptococci   2200   MPN/100ml
  Total Coliform   54000   MPN/100ml
  Sulphate   22.00   mg/l
  Nitrite N   0.04   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.10   mg/l
  Total Fixed Solids(TFS)   170.00   mg/l
  Total Hardness as CaCo3   112.96   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   10.00   mg/l
  Turbidity   28.80   NTU
  Ammonia-N   0.15   mg/l
  BOD   2.80   mg/l
  Potassium   8.10   mg/l
  Sodium   42.90   mg/l
  Total Alkalinity   129.43   mg/l
  Total Dissolved Solids(TDS)   258.00   mg/l
  Fluoride   0.57   mg/l
  Magnesium   4.50   mg/l