West Bengal Pollution Control Board

Hooghly Laboratory

Himalaya Bhawan, Delhi Road, Dankuni, Hooghly



Station: GANGA AT SERAMPORE, WEST BENGAL River Basin: GANGA CPCB Station Code: 1472
Sample Date: 04/02/2020 Sample Time: 13:00  
Human Activities: Bathing & washing Weather: Sunny,clear Water Body: GANGA AT SERAMPORE
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour Free Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  Nitrate-N   0.58   mg/l
  pH   8.25   Unit
  Temperature   21   ⁰C
  Total Coliform   240000   MPN/100ml
  Boron   BDL   mg/l
  Fluoride   0.17   mg/l
  Magnesium   13.10   mg/l
  Ammonia-N   0.12   mg/l
  BOD   3.20   mg/l
  Conductivity   383.6   µs/cm
  Calcium   39.22   mg/l
  Chloride   13.50   mg/l
  COD   15.00   mg/l
  Dissolved O2(DO)   11.70   mg/l
  E-coli   23000   MPN/100ml
  Fecal Coliform   50000   MPN/100ml
  Fecal Streptococci   500   MPN/100ml
  Potassium   4.50   mg/l
  Sodium   20.20   mg/l
  Sulphate   26.44   mg/l
  Total Alkalinity   157.89   mg/l
  Total Dissolved Solids(TDS)   170.00   mg/l
  Total Fixed Solids(TFS)   38.00   mg/l
  Total Hardness as CaCo3   151.96   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   36.00   mg/l
  Turbidity   42.30   NTU
  Nitrite N   0.32   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.0412   mg/l