West Bengal Pollution Control Board

Hooghly Laboratory

Himalaya Bhawan, Delhi Road, Dankuni, Hooghly



Station: GANGA AT SERAMPORE, WEST BENGAL River Basin: GANGA CPCB Station Code: 1472
Sample Date: 24/01/2020 Sample Time: 12:30  
Human Activities: Bathing & washing,Navigation Weather: Sunny,clear Water Body: GANGA AT SERAMPORE
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Muddy Odour: Odour Free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  BOD   3.25   mg/l
  Ammonia-N   0.26   mg/l
  Conductivity   360.70   µs/cm
  Dissolved O2(DO)   11.00   mg/l
  Fecal Coliform   23000   MPN/100ml
  Fecal Streptococci   300   MPN/100ml
  Nitrate-N   0.41   mg/l
  Temperature   19   ⁰C
  Total Coliform   50000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   40.00   mg/l
  Fluoride   0.21   mg/l
  Magnesium   12.15   mg/l
  Nitrite N   0.06   mg/l
  Phenolpthalein Alkanity   5.68   mg/l
  Phosphate-P   0.022   mg/l
  Potassium   3.40   mg/l
  Sodium   16.10   mg/l
  Sulphate   17.76   mg/l
  Total Alkalinity   147.72   mg/l
  Total Dissolved Solids(TDS)   120.00   mg/l
  Total Fixed Solids(TFS)   30.00   mg/l
  Total Hardness as CaCo3   150.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   30.00   mg/l
  Turbidity   37.80   NTU
  E-coli   17000   MPN/100ml
  pH   8.69   Unit
  Chloride   12.54   mg/l
  COD   8.33   mg/l