West Bengal Pollution Control Board

Hooghly Laboratory

Himalaya Bhawan, Delhi Road, Dankuni, Hooghly



Station: GANGA AT SERAMPORE, WEST BENGAL River Basin: GANGA CPCB Station Code: 1472
Sample Date: 19/11/2019 Sample Time: 14:15  
Human Activities: Navigation Weather: Sunny,clear Water Body: GANGA AT SERAMPORE
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: muddy Odour: Odour Free Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  BOD   6.10   mg/l
  Total Coliform   70000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   34.62   mg/l
  Chloride   9.64   mg/l
  COD   11.00   mg/l
  Phosphate-P   0.019   mg/l
  Potassium   3.90   mg/l
  Sodium   16.30   mg/l
  Sulphate   19.68   mg/l
  Total Alkalinity   142.3   mg/l
  pH   8.01   Unit
  Total Dissolved Solids(TDS)   180.00   mg/l
  Total Fixed Solids(TFS)   44.00   mg/l
  Total Hardness as CaCo3   129.81   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   98.00   mg/l
  Turbidity   99.80   NTU
  Ammonia-N   0.19   mg/l
  Conductivity   242.00   µs/cm
  Dissolved O2(DO)   6.30   mg/l
  E-coli   14000   MPN/100ml
  Fecal Coliform   40000   MPN/100ml
  Fecal Streptococci   300   MPN/100ml
  Nitrate-N   0.48   mg/l
  Fluoride   0.19   mg/l
  Magnesium   10.51   mg/l
  Temperature   28   ⁰C
  Nitrite N   0.27   mg/l
  Phenolpthalein Alkanity   0.0   mg/l