West Bengal Pollution Control Board

Hooghly Laboratory

Himalaya Bhawan, Delhi Road, Dankuni, Hooghly



Station: HATISHALA GHAT ON DUDHPUKUR AT TARAKESHWAR River Basin: GANGA CPCB Station Code: 2503
Sample Date: 26/02/2021 Sample Time: 12:10  
Human Activities: Bathing, Holy Dip Weather: Sunny Clear Water Body: Dudhpukur
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Light green Odour: nil Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.61   mg/l
  BOD   3.25   mg/l
  Conductivity   649.50   µs/cm
  Dissolved O2(DO)   9.60   mg/l
  Fecal Coliform   7900   MPN/100ml
  Nitrate-N   0.51   mg/l
  pH   8.46   Unit
  Temperature(Water)   26.0   ⁰C
  Total Coliform   11000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   45.81   mg/l
  Chloride   69.98   mg/l
  COD   12.74   mg/l
  Fluoride   0.52   mg/l
  Magnesium   14.88   mg/l
  Phenolpthalein Alkanity   10.16   mg/l
  Phosphate-P   0.14   mg/l
  Potassium   34.8   mg/l
  Sodium   72.9   mg/l
  Sulphate   21.78   mg/l
  Total Alkalinity   238.82   mg/l
  Total Dissolved Solids(TDS)   340.00   mg/l
  Total Fixed Solids(TFS)   324.00   mg/l
  Total Hardness as CaCo3   177.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   8.00   mg/l
  Turbidity   4.02   NTU