West Bengal Pollution Control Board

Hooghly Laboratory

Himalaya Bhawan, Delhi Road, Dankuni, Hooghly



Station: HATISHALA GHAT ON DUDHPUKUR AT TARAKESHWAR River Basin: GANGA CPCB Station Code: 2503
Sample Date: 15/12/2021 Sample Time: 13:55  
Human Activities: Holi-dip, bathing Weather: Sunny, Clear Water Body: Dudhpukur
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 0.00 m 
Color & Intensity: Light green Odour: Nil Visible effluent discharge: nil


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.40   mg/l
  BOD   5.60   mg/l
  Conductivity   579.70   µs/cm
  Dissolved O2(DO)   7.50   mg/l
  Fecal Coliform   1400   MPN/100ml
  Nitrate-N   0.67   mg/l
  pH   7.94   Unit
  Temperature(Water)   23   ⁰C
  Total Coliform   3300   MPN/100ml
  Boron   BDL   mg/l
  Calcium   44.70   mg/l
  Chloride   44.98   mg/l
  COD   19.00   mg/l
  Fluoride   0.45   mg/l
  Magnesium   25.23   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.12   mg/l
  Potassium   23.50   mg/l
  Sodium   34.10   mg/l
  Sulphate   19.24   mg/l
  Total Alkalinity   191.60   mg/l
  Total Dissolved Solids(TDS)   388.0   mg/l
  Total Fixed Solids(TFS)   334.0   mg/l
  Total Hardness as CaCo3   215.38   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   8.0   mg/l
  Turbidity   6.55   NTU