West Bengal Pollution Control Board

Siliguri Laboratory

Paribesh Bhawan, Paribahan Nagar, P.O. Matigara, Siliguri,Darjeeling 734 428.



Station: MAHANANDA D/S, RAMGHAT River Basin: Mahananda CPCB Station Code: 2525
Sample Date: 14/11/2019 Sample Time: 11:30 hrs  
Human Activities: NIL Weather: Sunny Water Body: Ramghat on Mahananda
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 1.00 m 
Color & Intensity: Dark Ash Odour: Septic Visible effluent discharge: Moderate


Water Quality
Parameter Test Result Unit
  Total Fixed Solids(TFS)   76.00   mg/l
  Total Dissolved Solids(TDS)   112.00   mg/l
  Total Hardness as CaCo3   80.00   mg/l
  Total Suspended Solids(TSS)   72.00   mg/l
  Turbidity   4.87   NTU
  Ammonia-N   1.69   mg/l
  BOD   12.00   mg/l
  Conductivity   110.60   µs/cm
  Dissolved O2(DO)   5.40   mg/l
  Fecal Coliform   90000   MPN/100ml
  pH   6.60   Unit
  Temperature   29   ⁰C
  Total Coliform   140000   MPN/100ml
  Boron   0.039   mg/l
  Calcium   28.06   mg/l
  Chloride   16.63   mg/l
  COD   68.00   mg/l
  Fluoride   0.20   mg/l
  Magnesium   2.88   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.046   mg/l
  Potassium   4.10   mg/l
  Sulphate   31.25   mg/l
  Total Alkalinity   84.00   mg/l
  Sodium   9.10   mg/l
  Nitrate-N   0.54   mg/l