West Bengal Pollution Control Board

Siliguri Laboratory

Paribesh Bhawan, Paribahan Nagar, P.O. Matigara, Siliguri,Darjeeling 734 428.



Station: TEESTA AT SEVOKE River Basin: Tista CPCB Station Code: 1947
Sample Date: 24/02/2021 Sample Time: 10.00  
Human Activities: None Weather: Sunny and Clear. Water Body: TEESTA AT SILIGURI
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 1.00 m 
Color & Intensity: Light Green Odour: Fishy Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   BDL   mg/l
  BOD   1.60   mg/l
  Conductivity   62.00   µs/cm
  Dissolved O2(DO)   7.40   mg/l
  Fecal Coliform   2200   MPN/100ml
  Fecal Streptococci   13   MPN/100ml
  Nitrate-N   0.16   mg/l
  pH   7.10   Unit
  Temperature(Water)   24   ⁰C
  Total Coliform   9000   MPN/100ml
  Boron   2.71   mg/l
  Calcium   12.02   mg/l
  Chloride   4.89   mg/l
  COD   28.00   mg/l
  Fluoride   BDL   mg/l
  Magnesium   2.88   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.002   mg/l
  Potassium   0.70   mg/l
  Sodium   1.40   mg/l
  Sulphate   7.11   mg/l
  Total Alkalinity   42.00   mg/l
  Total Dissolved Solids(TDS)   48.00   mg/l
  Total Fixed Solids(TFS)   92.00   mg/l
  Total Hardness as CaCo3   40.00   mg/l
  Total Suspended Solids(TSS)   18.00   mg/l
  Turbidity      NTU