West Bengal Pollution Control Board

Siliguri Laboratory

Paribesh Bhawan, Paribahan Nagar, P.O. Matigara, Siliguri,Darjeeling 734 428.



Station: TEESTA AT SEVOKE River Basin: Tista CPCB Station Code: 1947
Sample Date: 24/09/2021 Sample Time: 16:10  
Human Activities: None Weather: Sunny and Clear. Water Body: TEESTA AT SILIGURI
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Light Green and turbid Odour: Fishy Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   BDL   mg/l
  BOD   1.50   mg/l
  Conductivity   50.46   µs/cm
  Dissolved O2(DO)   8.10   mg/l
  Fecal Coliform   2200   MPN/100ml
  Fecal Streptococci   13   MPN/100ml
  Nitrate-N   0.08   mg/l
  pH   6.91   Unit
  Temperature(Water)   25   ⁰C
  Total Coliform   9000   MPN/100ml
  Boron   1.37   mg/l
  Calcium   8.82   mg/l
  Chloride   0.98   mg/l
  COD   14.00   mg/l
  Fluoride   0.15   mg/l
  Magnesium   2.88   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.001   mg/l
  Potassium   BDL   mg/l
  Sodium   0.5   mg/l
  Sulphate   3.42   mg/l
  Total Alkalinity   56.00   mg/l
  Total Dissolved Solids(TDS)   48.00   mg/l
  Total Fixed Solids(TFS)   44.00   mg/l
  Total Hardness as CaCo3   32.00   mg/l
  Total Suspended Solids(TSS)   19.00   mg/l
  Turbidity   24.80   NTU