West Bengal Pollution Control Board

Siliguri Laboratory

Paribesh Bhawan, Paribahan Nagar, P.O. Matigara, Siliguri,Darjeeling 734 428.



Station: TEESTA AT SEVOKE River Basin: Tista CPCB Station Code: 1947
Sample Date: 31/08/2021 Sample Time: 14:40  
Human Activities: None Weather: Sunny and Clear. Water Body: TEESTA AT SILIGURI
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 1.00 m 
Color & Intensity: Light Brown and moderately turbid Odour: Odour Free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   BDL   mg/l
  BOD   1.00   mg/l
  Conductivity   28.61   µs/cm
  Dissolved O2(DO)   7.80   mg/l
  Fecal Coliform   3400   MPN/100ml
  Fecal Streptococci   11   MPN/100ml
  Nitrate-N   0.12   mg/l
  pH   7.20   Unit
  Temperature(Water)   26   ⁰C
  Total Coliform   13000   MPN/100ml
  Boron   0.69   mg/l
  Calcium   11.22   mg/l
  Chloride   9.78   mg/l
  COD   10.00   mg/l
  Fluoride   0.13   mg/l
  Magnesium   1.73   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.002   mg/l
  Potassium   0.20   mg/l
  Sodium   1.0   mg/l
  Sulphate   3.48   mg/l
  Total Alkalinity   42.00   mg/l
  Total Dissolved Solids(TDS)   10.00   mg/l
  Total Fixed Solids(TFS)   24.00   mg/l
  Total Hardness as CaCo3   34.0   mg/l
  Total Suspended Solids(TSS)   8.00   mg/l
  Turbidity   39.60   NTU