West Bengal Pollution Control Board

Siliguri Laboratory

Paribesh Bhawan, Paribahan Nagar, P.O. Matigara, Siliguri,Darjeeling 734 428.



Station: River Mechi at Nehaljote River Basin: Mahananda CPCB Station Code: 4727
Sample Date: 17/03/2020 Sample Time: 14:30 Hrs  
Human Activities: Washing and Construction of Bridge. Weather: Sunny Water Body: Mechi
Frequency Of Monitoring: Monthly Use Based Class: B Approximate Depth(Bottom/Table): 1.00 m 
Color & Intensity: Light Green and Slightly Turbid Odour: None Visible effluent discharge: None.


Water Quality
Parameter Test Result Unit
  BOD   1.80   mg/l
  Conductivity   62.91   µs/cm
  Dissolved O2(DO)   8.60   mg/l
  Fecal Coliform   2100   MPN/100ml
  Nitrate-N      mg/l
  pH   7.80   Unit
  Total Coliform   5000   MPN/100ml
  Boron   2.81   mg/l
  Calcium   6.41   mg/l
  Chloride   4.89   mg/l
  COD   48.00   mg/l
  Fluoride      mg/l
  Magnesium   4.61   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.002   mg/l
  Potassium   1.20   mg/l
  Sodium   2.80   mg/l
  Sulphate   4.66   mg/l
  Total Alkalinity   36.00   mg/l
  Total Dissolved Solids(TDS)   82.00   mg/l
  Total Fixed Solids(TFS)      mg/l
  Total Hardness as CaCo3   32.00   mg/l
  Total Suspended Solids(TSS)   24.00   mg/l
  Turbidity      NTU
  Temperature   28   ⁰C
  Ammonia-N      mg/l