West Bengal Pollution Control Board

Siliguri Laboratory

Paribesh Bhawan, Paribahan Nagar, P.O. Matigara, Siliguri,Darjeeling 734 428.



Station: KOCHBIHAR LAKE (SAGAR DIGHI) River Basin: Raidak_Torsa CPCB Station Code: 2519
Sample Date: 21/12/2021 Sample Time: 13:05 Hrs  
Human Activities: None Weather: Sunny and Clear. Water Body: Coochbihar lake
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 1.00 m 
Color & Intensity: light Green and Turbid Odour: Fishy Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   BDL   mg/l
  BOD   2.20   mg/l
  Conductivity   39.45   µs/cm
  Dissolved O2(DO)   7.50   mg/l
  Fecal Coliform   400   MPN/100ml
  Nitrate-N   0.08   mg/l
  pH   7.51   Unit
  Temperature(Water)   21   ⁰C
  Total Coliform   1300   MPN/100ml
  Boron   1.68   mg/l
  Calcium   10.42   mg/l
  Chloride   6.84   mg/l
  COD   13.47   mg/l
  Fluoride   BDL   mg/l
  Magnesium   1.152   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.005   mg/l
  Potassium   1.40   mg/l
  Sodium   2.80   mg/l
  Sulphate   0.21   mg/l
  Total Alkalinity   40.00   mg/l
  Total Dissolved Solids(TDS)   21.00   mg/l
  Total Fixed Solids(TFS)   16.00   mg/l
  Total Hardness as CaCo3   26.00   mg/l
  Total Suspended Solids(TSS)   34.00   mg/l
  Turbidity   8.07   NTU