West Bengal Pollution Control Board

Durgapur Laboratory

Sahid Kshudiram Sarani, City Centre, Durgapur, Burdwan 713 216.(0343) 2543525



Station: River Damodar at Andal U/s River Basin: Damodar CPCB Station Code: 10107
Sample Date: 08/03/2022 Sample Time: 12:50  
Human Activities: Bathing & washing Weather: Sunny, Clear Water Body: Damodar
Frequency Of Monitoring: Monthly Use Based Class: A Approximate Depth(Bottom/Table): 0.25 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.62   mg/l
  BOD   3.15   mg/l
  Conductivity   432.30   µs/cm
  Dissolved O2(DO)   8.4   mg/l
  Fecal Coliform   3200   MPN/100ml
  Fecal Streptococci   17   MPN/100ml
  Nitrate-N   0.357   mg/l
  pH   7.79   Unit
  Temperature(Water)   28.0   ⁰C
  Total Coliform   6300   MPN/100ml
  Boron   BDL   mg/l
  Calcium   34.744   mg/l
  Chloride   23.86   mg/l
  COD   26.46   mg/l
  Fluoride   0.82   mg/l
  Magnesium   6.87   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.208   mg/l
  Potassium   7.7   mg/l
  Sodium   45.7   mg/l
  Sulphate   18.259   mg/l
  Total Alkalinity   122.00   mg/l
  Total Dissolved Solids(TDS)   300.00   mg/l
  Total Fixed Solids(TFS)   198.00   mg/l
  Total Hardness as CaCo3   115.14   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   10.00   mg/l
  Turbidity   19.6   NTU