West Bengal Pollution Control Board

Durgapur Laboratory

Sahid Kshudiram Sarani, City Centre, Durgapur, Burdwan 713 216.(0343) 2543525



Station: WATER INTAKE POINT FOR BURDWAN TOWN River Basin: Damodar CPCB Station Code: 2527
Sample Date: 13/10/2020 Sample Time: 11:45  
Human Activities: Bathing & washing, Fishing Weather: Sunny, Clear Water Body: Damodar at Burdwan
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 1.50 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Dissolved O2(DO)   8.2   mg/l
  Fecal Coliform   1700   MPN/100ml
  Nitrate-N   0.154   mg/l
  pH   7.40   Unit
  Temperature(Water)   32.0   ⁰C
  Total Coliform   4600   MPN/100ml
  Boron   NT   mg/l
  Calcium   24.49   mg/l
  Chloride   10.99   mg/l
  COD   12.50   mg/l
  Fluoride   0.414   mg/l
  Magnesium   5.54   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.344   mg/l
  Potassium   3.0   mg/l
  Sodium   17.1   mg/l
  Sulphate   49.94   mg/l
  Total Alkalinity   86.00   mg/l
  Total Dissolved Solids(TDS)   148.00   mg/l
  Total Fixed Solids(TFS)   102.00   mg/l
  Total Hardness as CaCo3   84.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   12.00   mg/l
  Turbidity   6.66   NTU
  Ammonia-N   0.298   mg/l
  BOD   1.95   mg/l
  Conductivity   227.60   µs/cm