Station: WATER INTAKE POINT FOR BURDWAN TOWN River Basin: Damodar CPCB Station Code: 2527
Sample Date: 06/12/2019 Sample Time: 15:30  
Human Activities: Bathing & washing Weather: Sunny, Clear Water Body: Damodar at Burdwan
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 0.50 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.263   mg/l
  BOD   2.85   mg/l
  Conductivity   238.90   µs/cm
  Dissolved O2(DO)   7.8   mg/l
  Fecal Coliform   2100   MPN/100ml
  pH   7.63   Unit
  Temperature   24.0   ⁰C
  Total Coliform   3800   MPN/100ml
  Boron   NT   mg/l
  Calcium   23.76   mg/l
  Chloride   12.33   mg/l
  COD   16.19   mg/l
  Fluoride   0.467   mg/l
  Magnesium   10.10   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   BDL   mg/l
  Potassium   7.48   mg/l
  Sodium   41.40   mg/l
  Sulphate   32.130   mg/l
  Total Alkalinity   98.00   mg/l
  Total Dissolved Solids(TDS)   206.00   mg/l
  Total Fixed Solids(TFS)   166.00   mg/l
  Total Hardness as CaCo3   100.98   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   22.00   mg/l
  Turbidity   26.16   NTU
  Nitrate-N   0.250   mg/l