West Bengal Pollution Control Board

Durgapur Laboratory

Sahid Kshudiram Sarani, City Centre, Durgapur, Burdwan 713 216.(0343) 2543525



Station: WATER INTAKE POINT FOR BANKURA TOWN ON RIVER DWARAKESHWAR River Basin: Damodar CPCB Station Code: 2541
Sample Date: 12/07/2022 Sample Time: 12:20  
Human Activities: Bathing & Washing Weather: Rainy Water Body: Dwarkeswar at bankura
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 0.25 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   0.36   mg/l
  BOD   2.80   mg/l
  Conductivity   197.4   µs/cm
  Dissolved O2(DO)   7.7   mg/l
  Fecal Coliform   2600   MPN/100ml
  Fecal Streptococci   33   MPN/100ml
  Nitrate-N   0.066   mg/l
  pH   7.36   Unit
  Temperature(Water)   26.0   ⁰C
  Total Coliform   4600   MPN/100ml
  Boron   BDL   mg/l
  Calcium   23.20   mg/l
  Chloride   10.85   mg/l
  COD   20.40   mg/l
  Fluoride   0.55   mg/l
  Magnesium   5.83   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.317   mg/l
  Potassium   2.6   mg/l
  Sodium   9.5   mg/l
  Sulphate   15.222   mg/l
  Total Alkalinity   96.00   mg/l
  Total Dissolved Solids(TDS)   162.00   mg/l
  Total Fixed Solids(TFS)   130.00   mg/l
  Total Hardness as CaCo3   82.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   10.00   mg/l
  Turbidity   8.55   NTU