West Bengal Pollution Control Board

Durgapur Laboratory

Sahid Kshudiram Sarani, City Centre, Durgapur, Burdwan 713 216.(0343) 2543525



Station: WATER INTAKE POINT FOR BANKURA TOWN ON RIVER DWARAKESHWAR River Basin: Damodar CPCB Station Code: 2541
Sample Date: 01/06/2022 Sample Time: 12:55  
Human Activities: Bathing & Washing Weather: Sunny, Clear Water Body: Dwarkeswar at bankura
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 0.50 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Total Hardness as CaCo3   80.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   6.00   mg/l
  Turbidity   4.86   NTU
  Boron   BDL   mg/l
  Total Fixed Solids(TFS)   156.00   mg/l
  BOD   2.75   mg/l
  Conductivity   213.80   µs/cm
  Dissolved O2(DO)   7.6   mg/l
  Fecal Coliform   1700   MPN/100ml
  Fecal Streptococci   17   MPN/100ml
  Nitrate-N   0.202   mg/l
  pH   7.91   Unit
  Temperature(Water)   34.5   ⁰C
  Total Coliform   3200   MPN/100ml
  Calcium   20.80   mg/l
  Chloride   20.61   mg/l
  COD   21.84   mg/l
  Fluoride   0.43   mg/l
  Magnesium   6.80   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.058   mg/l
  Potassium   2.1   mg/l
  Sodium   18.6   mg/l
  Sulphate   61.788   mg/l
  Total Alkalinity   70.00   mg/l
  Total Dissolved Solids(TDS)   172.00   mg/l
  Ammonia-N   0.32   mg/l