West Bengal Pollution Control Board

Central Laboratory

Paribesh Bhawan, 10A, Block LA, Sector III, Salt Lake City, Kolkata 700 106. (033) 2335-5953



Station: GANGA AT DIAMOND HARBOUR, WEST BENGAL River Basin: GANGA CPCB Station Code: 1469
Sample Date: 01/06/2020 Sample Time: 12:30  
Human Activities: Bathing & washing, fishing Weather: Sunny Water Body: Ganga
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Muddy Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Chloride   629.80   mg/l
  Magnesium   28.59   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Nitrite N   0.01   mg/l
  pH   8.11   Unit
  Total Suspended Solids(TSS)   1116.00   mg/l
  BOD   1.80   mg/l
  Fecal Streptococci   20   MPN/100ml
  Fecal Coliform   8000   MPN/100ml
  Phosphate-P   1.37   mg/l
  Potassium   11.89   mg/l
  Sodium   134.43   mg/l
  Sulphate   14.76   mg/l
  Total Alkalinity   200.00   mg/l
  Total Dissolved Solids(TDS)   1284.00   mg/l
  Total Fixed Solids(TFS)   2156.00   mg/l
  Total Hardness as CaCo3   254.90   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Turbidity   620.00   NTU
  Ammonia-N   0.12   mg/l
  Conductivity   1686.00   µs/cm
  Dissolved O2(DO)   6.50   mg/l
  E-coli   4500   MPN/100ml
  Boron   BDL   mg/l
  Nitrate-N   0.75   mg/l
  Total Coliform   13000   MPN/100ml
  Calcium   54.90   mg/l
  Temperature(Water)   30.0   ⁰C
  COD   18.00   mg/l
  Fluoride   0.23   mg/l