Station: GANGA AT DIAMOND HARBOUR, WEST BENGAL River Basin: GANGA CPCB Station Code: 1469
Sample Date: 03/09/2019 Sample Time: 14:10  
Human Activities: Bathing & washing Weather: Cloudy Water Body: Ganga
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 2.00 m 
Color & Intensity: Mod Brown Odour: Fishy Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Temperature   36.0   ⁰C
  Chloride   379.89   mg/l
  Total Hardness as CaCo3   211.53   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Fecal Streptococci   20   MPN/100ml
  Total Coliform   11000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   42.31   mg/l
  Conductivity   2170.00   µs/cm
  Turbidity   258.00   NTU
  COD   16.66   mg/l
  Fluoride   0.31   mg/l
  Magnesium   24.75   mg/l
  Nitrite N   0.04   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Potassium   16.26   mg/l
  Sodium   375.39   mg/l
  Sulphate   137.70   mg/l
  Total Alkalinity   100.80   mg/l
  Total Dissolved Solids(TDS)   1038.00   mg/l
  Total Fixed Solids(TFS)   1272.00   mg/l
  Total Suspended Solids(TSS)   328.00   mg/l
  Ammonia-N   0.16   mg/l
  BOD   2.05   mg/l
  Dissolved O2(DO)   4.30   mg/l
  Fecal Coliform   1400   MPN/100ml
  Nitrate-N   2.52   mg/l
  pH   7.68   Unit
  Phosphate-P   BDL   mg/l
  E-coli   400   MPN/100ml