West Bengal Pollution Control Board

Central Laboratory

Paribesh Bhawan, 10A, Block LA, Sector III, Salt Lake City, Kolkata 700 106. (033) 2335-5953



Station: HIDCO OFFICE, RAJARHAT River Basin: GANGA CPCB Station Code: 2548
Sample Date: 05/10/2021 Sample Time: 12:20  
Human Activities: Drinking & Domestic Weather: Cloudy Water Body: null
Frequency Of Monitoring: Halfyearly Use Based Class: A Approximate Depth(Bottom/Table): 0.00 m 
Color & Intensity: Clear Odour: Odour free Visible effluent discharge: None


Water Quality
Parameter Test Result Unit
  Ammonia-N   BDL   mg/l
  BOD   1.25   mg/l
  Conductivity   253.60   µs/cm
  Fecal Coliform   4   MPN/100ml
  Nitrate-N   0.51   mg/l
  pH   7.40   Unit
  Temperature(Water)   30.0   ⁰C
  Total Coliform   33   MPN/100ml
  Boron   BDL   mg/l
  Calcium   24.00   mg/l
  Chloride   29.99   mg/l
  COD   11.00   mg/l
  Fluoride   0.33   mg/l
  Magnesium   9.72   mg/l
  Phenolpthalein Alkanity   NIL   mg/l
  Phosphate-P   0.04   mg/l
  Potassium   3.09   mg/l
  Sodium   27.13   mg/l
  Sulphate   17.12   mg/l
  Total Alkalinity   140.00   mg/l
  Total Dissolved Solids(TDS)   100.00   mg/l
  Total Fixed Solids(TFS)   32.00   mg/l
  Total Hardness as CaCo3   100.00   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   66.00   mg/l
  Turbidity   3.58   NTU
  Arsenic   BDL   mg/l
  Cadmium   BDL   mg/l
  Chromium Total   BDL   mg/l
  Copper   BDL   mg/l
  Iron   0.12   mg/l
  Lead   BDL   mg/l
  Mercury   BDL   mg/l
  Nickel   BDL   mg/l
  Zinc   BDL   mg/l
  a-BHC   BDL   ppb
  a-Endosulphan   BDL   ppb
  Aldrin   BDL   ppb
  Anilophos   BDL   ppb
  b-Endosulphan   BDL   ppb
  Chlorpyriphos   BDL   ppb
  Dieldrin   BDL   ppb
  g-BHC   NT   ppb
  Malathion   BDL   ppb
  Methyl Parathion   BDL   ppb
  o,p-DDT   NT   ppb
  p,p-DDT   BDL   ppb