West Bengal Pollution Control Board

Kankinara Laboratory

Panpore More, Kalyani Expressway, Vill. Panpur, P.O. Narrayanpur, Dist: 24-Parganas (N), Pin 743 126,(033) 2502-1189



Station: NOAI CANAL NORTH 24 PARGANAS, NEAR GANGA NAGAR MOTIBRIDGE River Basin: GANGA CPCB Station Code: 2512
Sample Date: 07/09/2021 Sample Time: 12:30  
Human Activities: Slum dwellers activity Weather: Rainy,Humid Water Body: Noai Canal
Frequency Of Monitoring: Quarterly Use Based Class: C Approximate Depth(Bottom/Table): 3.00 m 
Color & Intensity: Blackish Odour: Rotten eggs,Septic Visible effluent discharge: High


Water Quality
Parameter Test Result Unit
  Ammonia-N   3.89   mg/l
  BOD   33.00   mg/l
  Conductivity   561.80   µs/cm
  Dissolved O2(DO)   0.80   mg/l
  Fecal Coliform   1700000   MPN/100ml
  Fecal Streptococci   350000   MPN/100ml
  Nitrate-N   1.47   mg/l
  pH   7.17   Unit
  Temperature(Water)   31   ⁰C
  Total Coliform   2800000   MPN/100ml
  Boron   BDL   mg/l
  Calcium   39.29   mg/l
  Chloride   45.00   mg/l
  COD   57.00   mg/l
  Fluoride   1.15   mg/l
  Magnesium   21.92   mg/l
  Phenolpthalein Alkanity   Nil   mg/l
  Phosphate-P   0.50   mg/l
  Potassium   6.70   mg/l
  Sodium   47.80   mg/l
  Sulphate   20.74   mg/l
  Total Alkalinity   194.45   mg/l
  Total Dissolved Solids(TDS)   294.00   mg/l
  Total Fixed Solids(TFS)   266.00   mg/l
  Total Hardness as CaCo3   188.24   mg/l
  Total Kjeldahl Nitrogen(TKN)      mg/l
  Total Suspended Solids(TSS)   36.00   mg/l
  Turbidity   25.10   NTU